This site uses cookies to provide an optimized shopping experience. By using this site, you agree the use of cookies within our privacy policy.
Fluke II910
Precision Acoustic Imager
The Fluke ii910 is a Precision Acoustic Imager that safely and quickly detects and locates Partial Discharge (PD), as well as Gas and Vacuum Leaks. Problem areas are translated into visual representation to quickly locate the problem.
- MecQ mechanical scanning
- PD detection detects Corona and Partial Discharge, even when there is no direct line of sight
- Cut costs and save energy every day by taking the guesswork out of finding and fixing partial discharge
- MecQ™ mechanical scanning mode
- Partial discharge detection detects Corona and Partial Discharge (PD), even when there is no direct line of sight
- Cut costs and save energy everyday by taking the guesswork out of finding and fixing partial discharge
- High sensitivity allows users to detect PD at earlier stages, enabling condition-base maintenance and planning service of equipment (vs preventive replacing/servicing/cleaning)
- SoundSight™ technology translates sounds into visual representation so that users can easily scan and quickly locate problem areas
- Ease of use allows untrained users to detect, locate, and assess severity of Partial Discharge, Corona Discharge or Gas/Vacuum leaks, easier, faster, and more effectively than existing Ultrasonic Tools, by using visual images to better pinpoint and report PD, Corona or Gas leak
- PDQ Mode™ provides relative severity of discharge, which provides information to users on whether action may or may not be needed after PD has been detected
- LeakQ™ estimates size and cost of leak, including new distance-estimation feature and 1-10 LeakQ™ severity index
- Images can be uploaded online to generate leak reports including leak size and cost estimation
- Video recording up to 5 minutes can capture behavior of identified problem or capture larger environment to review at later stage potential spots to review in further detail
- 64 special designed and positioned MEM microphones in sensor head as well as proper algorithms to efficiently process data providing users with optimal detection capabilities
Sensors
- Frequency band: 2 kHz to 100 kHz
- Detection range: 0.5 m to 120 m (1.6 to 393 feet), depending on ambient conditions
- Field of view: 63°± 5°
- Nominal frame rate: 25 FPS (number of Frames Per Second (FPS) indicates number of times image on screen is refreshed each second)
Built-in digital camera (visible light)
- Field of view (FOV): 63°± 5°
- Focus: Fixed lens
Display
- Size: 7 in. LCD with backlight, sunlight readable
- Resolution: 1280 x 800 (1,024,000 pixels)
- Touchscreen: Capacitive (extremely precise and quick responding)
- Acoustic image: Yes, SoundMap™ image (visual map of noise sources using acoustical array)
Image Storage
- Storage capacity: Internal memory with capacity for 999 picture files and 20 video files
- Image format: Blended visual and SoundMap™ .JPG or .PNG
- Video format: Blended visual and SoundMap™ .MP4
- Video length: Up to 5 minutes
- Digital export: USB-C for data transfer
Acoustic Measurements
- Measurement range:
- 12.1 dB SPL to 114.6 dB SPL; ±1 dB SPL 2 kHz
- 4.4 dB SPL to 101.2 dB SPL; ±2 dB SPL 19 kHz
- 12.8 dB SPL to 119.2 dB SPL; ±1 dB SPL 35 kHz
- 19.8 dB SPL to 116.1 dB SPL; ±3 dB SPL 52 kHz
- 41.4 dB SPL to 129.0 dB SPL; ±1 dB SPL 80 kHz
- 54.4 dB SPL to 135.5 dB SPL; ±1 dB SPL 100 kHz
- Sound pressure level (dB SPL) or acoustic pressure is local pressure deviation from ambient-decible and sound pressure level
- Auto max/min dB gain: Auto or manual, user selectable
- Frequency band selection: User selectable through user-made presets or manual entry
Software
- Ease of use: Intuitive user interface
- Trend graphs: Frequency and dB scale
- Spot markers: dB level reading at center point of image
Battery
- Batteries (field-replaceable, rechargeable): 2 x Rechargeable Li-ion, Fluke BP291
- Battery life: 6 hours/battery (product includes spare battery)
- Battery charging time: 3 hours
- Battery charging system: External dual-bay charger, EDBC 290
General Specifications
- Standard palettes: Grayscale, Ironbow and Blue-Red
- Operating temperature: -10 °C to 40 °C (14 °F to 104 °F)
- Storage temperature: -20 °C to 70 °C ( -4 °F to 158 °F) without batteries installed
- Relative humidity: 10% to 95% non-condensing
- Size: (H x W x L): 186mm x 322mm x 68mm (7.3 inches x 12.7 inches x 2.7 inches)
- Ingress Protection (IP): IP40 (protection against particles 1mm or greater and dripping water)
- Warranty: 2 years
- Self-diagnostic notification: Array-health test to identify when microphone array needs attention
- Supported languages: Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese
- RoHS compliant: Yes
- General safety: IEC 61010-1
Applications
- Industrial and Power Distribution
- High Voltage Transmission Utility
- OEM and Service Provider
Key Areas to scan for Partial Discharge (PD)
- Insulators
- Transformers
- High voltage powerlines
- Switch gears
- Arrestors
- Busbars
- High voltage coils
- Breakers
- Capacitors
Leaks in compressed air, gas, steam and vacuum systems hurt both production uptime and the operations bottom line.
While most manufacturers know that these types of leaks exist, it has been too time consuming and tedious to address them until now. With the Fluke ii910 Precision Acoustic Imager and minimal training, your maintenance technicians can begin checking for leaks during their typical maintenance routine-even during peak operation hours.
The ii910 acoustic imagers let technicians see sound as they scan hoses, fittings, and connections for leaks. Its built-in acoustic array of tiny sensitive microphones generates a spectrum of decibel levels per frequency. Based on this output, an algorithm calculates a sound image, known as SoundMap™ that is superimposed on a visual image. The SoundMap is automatically adapted depending on the frequency level selected so that background noise is filtered out, making it incredibly simple to detect compressed gas leaks.
Finally a better way to detect compressed air, gas, steam and vacuum leaks. Plus, the ii910 provides increased sensitivity to detect leaks that are smaller or farther away.
The invisible threat you can now see
Partial Discharge is a very serious issue that you would like to be able to monitor quickly and easily. Whether you are inspecting insulators, transformers, switch gears or high voltage powerlines you need to be sure that you spot a problem quickly and early. Partial discharge that goes unchecked can cause blackouts, fires, explosions, or death from arc flashes. In addition to the danger that partial discharge poses to human lives and the environment, there is a significant monetary risk of downtime. Having equipment go down can cost millions of dollars per hour of downtime.
The Fluke ii910 Precision Acoustic Imager is the perfect tool for high voltage electricians, electrical test engineers, and grid maintenance teams that are constantly inspecting and maintaining power distribution and industrial high voltage equipment. The ii910 provides a safe quick and easy way to detect and locate partial discharge in order to maintain high voltage equipment and prevent catastrophic events. With the SoundSight™ technology the ii910 translates the sounds that it hears into a visual representation so that you can quickly locate problem areas. The higher frequency capability of the ii910 allows for earlier detection to facilitate early maintenance planning and is why the ii910 has a frequency range of 2-100Khz.
Mechanical: first-line inspection to locate potential mechanical issues early and avoid unplanned downtime
Conveyor systems are a daunting maintenance problem because of the size and scope of the equipment and the nearly endless number of components that have the potential to disrupt production and cause unplanned downtime. Until now, it has been almost impossible to inspect the systems properly. The Fluke ii900 with MecQ revolutionizes inspection by enabling efficient scanning of large areas to detect and document potential issues for more targeted maintenance. With contactless scanning and advanced noise filtering, the Fluke ii910 Precision Acoustic Imager with MecQ™ Mode ensures safety and delivers clear images even in high-noise environments. By detecting areas of concern early on, it enables proactive measures to prevent costly problems, surpassing traditional methods. For professionals seeking seamless operation and proactive maintenance of large conveyance systems, the Fluke ii910 Precision Acoustic Imager with MecQ™ is the ultimate choice.
Country of Origin | Romania |
---|---|
Brand | Fluke |
Condition | NEW |
UPC | 195112008164 |
Catalog | 5233904 |
Vendor Alias | FLK-II910 |
- 1 - ii910 Precision Acoustic Imager
- 1 - AC Power Supply and Battery Pack Charger with Universal AC Adapters
- 2 - Rugged Lithium Ion Smart Battery Packs**
- 1 - USB Cable
- 1 - Rugged, Hard Carrying Case
- 2 - Rubber Array Covers
- 1 - Adjustable Hand Strap and Adjustable Neck Strap
**All Fluke ii900 and ii910 Acoustic Imagers will be supplied with a single battery and a voucher. This voucher includes a clear instruction on how to claim the second battery online.